Message management for oversized panes

From Opera Wiki

(Difference between revisions)
Jump to: navigation, search
 
(7 intermediate revisions not shown)
Line 1: Line 1:
-
[[Image:parametriottimizzazionepiana_.png|thumb|500px|]]
+
[[Image:flatoptimizationparameters.png|thumb|500px|]]
-
{{NB|To access this box in Opera Job Management: from ''Accessories'', select the button [[File:Tastoottimizzazioneriempimenti_.png]]}}
+
{{NB|To access this box in Opera Job Management: from the “Accessories Archive”, select the [[File:filloptimizationbutton.png fills]] button.}}
 +
The purpose of this archive is to manage the size limits of the fill and the messages in the prints.
 +
It also allows you to manage the integrated Flat Optimization, if the corresponding step is activated.
 +
{{BR}}
-
The purpose of this archive is to manage the size limits of the filling and manage the messages in the prints.
+
== Section 1: the vein setting ==
-
Below is a description of the contents of the framework:
+
*”’Vein type”’ [[File:dropdownmenubutton.png]]: field for the choice of the type of vein filling (“None, Horizontal Vein, Vertical Vein”) and is related to the cutting management of the sheet. It’s a valid field whether you handle the filling in m2 or in pieces. In the first case, in the Fill List, the order can contain, if set both the type of vein and its dimensions. In the second case, we talk about Flat plate optimization, so check the dedicated section.
 +
{{BR}}
-
*'''2D optimization''' (optional step): If active, it optimizes for this filling based on the size set in the following fields.
+
== Section 2: Fields for integrated flat optimization ==
-
**'''Stock W/Stock H''': width and height of the filling to be optimized.
+
 +
*”’Flat optimization” “’(optional step)”’: If enabled, it optimizes for this fill based on the dimensions set in the following fields.
-
{{NB| For its use see the page on this manual [[How to manage Integrated plane optimization step]]}}
 
-
*'''Vein Type''' [[File:tastomenutendina.png]]: field for the selection of the fill vein type (''None, Horizontal Vein, Vertical Vein'').
+
{{NB|The fields described below are activated only with the Flat Optimization step. For its use check the page on this manual [[How to manage the step Integrated plane optimization]]}}
-
*'''Max. W/Max. H'': maximum dimensions of filling.
+
**”’The plate/H plate”’: width and height of the filling to be optimized.
-
*'''Max. area''': Area for calculating muntin bars.
+
**”’Divide out of range”’: divides cuts beyond the size of the sheet. The Flat optimization performed on the basis of the dimensions of the sheet set in the fields L sheet and H sheet is calculated in pieces. The parts of the sheet that exceed the set measurements are divided and calculated in m2.
-
*'''Surface calculation type''' [[File:tastomenutendina.png]: indicates which surface is taken into account for the calculation (''Fill, Surface in view'')
+
**”’Overlap”’: field to set the overlap size of the split pieces.
-
*'''Print message when exceeding''': If active, prints an error message when filling exceeds the maximum size.
+
 
 +
 
 +
{{NB|
 +
The fields “Divide out of range” and “Overlap” are useful in the management of folded profiles (used for example in the Curtain wall).}}
 +
 
 +
{{BR}}
 +
 
 +
== Section 3: Fields for message handling and fill size ==
 +
 
 +
 
 +
*”’Default tolerance/Excess tolerance”’: in this field we define the tolerance in rounding (down or over) of the dimensions of the filling. The fields are useful in the dimensioning of fillings on fixtures with multiple structures ( e.g. a window) that by their design are composed of different structures in different sizes. Indicating the tolerance for fillings allows you to size them all to the same dimension.
 +
 
 +
 
 +
*”’Max. L/Max. H”’: maximum dimensions of filling.
 +
*'''Maximum area”’: Area for calculating muntins.
 +
*”’Surface Calculation Type”’ [[File:dropdownmenubutton.png]]: indicates which surface is taken into account for the calculation (“Fill, Surface in view”)
 +
*”’Print message when exceeding”’: If active, prints an error message when filling exceeds the maximum size.
== Related entries ==
== Related entries ==
-
*[[How to manage Integrated plane optimization step]]
+
*[[How to manage Optimization 2D]]

Latest revision as of 15:44, 8 November 2023

Note N.B: To access this box in Opera Job Management: from the “Accessories Archive”, select the File:Filloptimizationbutton.png fills button.

The purpose of this archive is to manage the size limits of the fill and the messages in the prints. It also allows you to manage the integrated Flat Optimization, if the corresponding step is activated.


Contents

Section 1: the vein setting

  • ”’Vein type”’ File:Dropdownmenubutton.png: field for the choice of the type of vein filling (“None, Horizontal Vein, Vertical Vein”) and is related to the cutting management of the sheet. It’s a valid field whether you handle the filling in m2 or in pieces. In the first case, in the Fill List, the order can contain, if set both the type of vein and its dimensions. In the second case, we talk about Flat plate optimization, so check the dedicated section.



Section 2: Fields for integrated flat optimization

  • ”’Flat optimization” “’(optional step)”’: If enabled, it optimizes for this fill based on the dimensions set in the following fields.


Note N.B: The fields described below are activated only with the Flat Optimization step. For its use check the page on this manual How to manage the step Integrated plane optimization
    • ”’The plate/H plate”’: width and height of the filling to be optimized.
    • ”’Divide out of range”’: divides cuts beyond the size of the sheet. The Flat optimization performed on the basis of the dimensions of the sheet set in the fields L sheet and H sheet is calculated in pieces. The parts of the sheet that exceed the set measurements are divided and calculated in m2.
    • ”’Overlap”’: field to set the overlap size of the split pieces.


Note N.B: The fields “Divide out of range” and “Overlap” are useful in the management of folded profiles (used for example in the Curtain wall).


Section 3: Fields for message handling and fill size

  • ”’Default tolerance/Excess tolerance”’: in this field we define the tolerance in rounding (down or over) of the dimensions of the filling. The fields are useful in the dimensioning of fillings on fixtures with multiple structures ( e.g. a window) that by their design are composed of different structures in different sizes. Indicating the tolerance for fillings allows you to size them all to the same dimension.


  • ”’Max. L/Max. H”’: maximum dimensions of filling.
  • Maximum area”’: Area for calculating muntins.
  • ”’Surface Calculation Type”’ File:Dropdownmenubutton.png: indicates which surface is taken into account for the calculation (“Fill, Surface in view”)
  • ”’Print message when exceeding”’: If active, prints an error message when filling exceeds the maximum size.